Page 23 - Demo
P. 23
Table 11 shows the conversion coefficient values (a) based on empirical relations. The layerthickness of the insulating materials is (t) in meters, and (l) is the heat transfer coefficient of theinsulating layer [according to equation (1)]. Equation (2) shows the value of the GWP index for1 kg of insulating material (CO2-eq.), an insulating area in square meters (A), insulatingmaterial density in kilograms per cubic meter (r) and insulating thickness in meters (t).Figure 17 shows the Pareto optimization results based on two goals, i.e. simultaneouslyreducing the building energy consumption and the environmental impacts of the insulatingmaterials.4.6 Model validationTo validate the model, a building in Karaj was modeled in eQuest software. Then, an annualenergy consumption analysis was performed for four insulating combinations. Finally,environmental impacts were computed for each compound. The responses were plotted onthe proposed model and measured for their distance from the Pareto front. It is worthmentioning that materials were ranked based on the distance to the Pareto front. Table 12shows four insulation scenarios with the energy analysis results and LCA. Figure 18 showsthe results of the building energy analysis and material LCA in the Pareto chart. Based onthe smaller distance, the ranking of two criteria was performed after measuring the distanceof these options on the chart (according to Table 13).The results showed that there is a significant relationship between the building’s annualenergy consumption and the surface heat transfer coefficient of the building walls. In this way,a lower surface heat transfer coefficient can be obtained by increasing the thickness of theinsulation layer. That is, reducing this coefficient will reduce energy loss and, as a result, reducethe building’s energy consumption. Today, due to the release of various environmentalpollutants in the production process of each product, special attention has been paid to productswith fewer environmental effects. One of the most common indicators is carbon latent inmaterials, which was determined by calculating the CO2-eq. through product LCA. Theinvestigations showed that different insulating materials have different environmental effects.Although a direct relationship between surface heat transfer coefficient and environmentaleffects was not observed. However, by using the concept of dominance in multi-objectiveoptimization problems, it became possible to choose a combination of insulation that has theleast environmental effects.Table 10.Ranking of 37 modesby comparing bothobjective functionsRank 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Section R6 R4 G4 G6 R7 E7 E6 R2 P6 E2 R3 G7 G2 R1 S7 E3 P4 S4 G3Rank 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37Section E1 R5 P7 E5 E4 G1 P2 S2 G5 P3 S3 P1 S1 B&W S5 P5 S4 MDFSource: Authors’ own creationTable 11.Experimental valuesof the conversionfactorR (m2K/W) 0.5–3 3–4 4–5 5–6 6–7 7–10a (khm2 K) 18E03 32E03 38E03 45E03 52E03 63E03Source: Authors’ own creationIJESM

