                                    The scope of this research is the investigation of the building’s inner shell, including the coveringof the floor, roof and walls. Fixed parameters such as structural elements, facades and the core ofexternal walls, which cannot be changed in building reconstruction, have been excluded fromthe scope of the research. The energy sources used in this building are natural gas and electricityfrom the grid. The location of this research is a 70-square-meter apartment on the top floor of a40-unit building in Karaj. Other limitations: The cooling and heating system and internal wallswere assumed to be fixed and unchangeable in the optimization process.In this research, the independent variable is different insulating materials, and the surface heattransfer coefficient value was used as a material’s representative in the quantitative relationships.Dependent variables include the annual building energy consumption during its 60-year life spanand the environmental impacts of insulation materials. ANSI/ASHRAE/IES 90.1 standards andIran’s national standard (No. 14253) were used to optimize energy consumption. The ISO 14040standards and Iran’s national standard (No. 21874) were used in the LCA section.3.1 Preliminary results of base building energy analysisThe energy analysis results show that the building’s energy consumption is equal to24,587.86 kWh/year without thermal insulation. According to the area of the apartment, thisamount of energy is equal to 356.83 kWh/m2. Table 2 shows the results of energy analysis inDesignBuilder.Table 1.BuildingspecificationsExternal wall ¼ 65.22 m2Materials Plaster Clay block Cement mortar Granite stoneThickness (m) 0.03 0.2 0.02 0.02(U-value ¼ 1.642 W/m2K)Roof ¼ 76 m2Materials Plaster Beam and block Cement mortar Mosaic InsulationThickness (m) 0.03 0.25 0.02 0.02 0.005(U-value ¼ 0.99 W/m2K)WindowsClear single-glazed (THK ¼ 2 mm, area ¼ 10.15 m2, U-value ¼5.894 W/m2K)Window frames IronExternal door Wooden, single-flush (U-value 2.1944 W/m2K)Heating system Radiator heating boilerLighting system FluorescentPopulation density (per square meter) 0.0169Occupancy schedule 24 hSource: Authors’ own creationTable 2.Preliminary resultsof building energyanalysisItem Value (kWh)Lighting 1,991.94Home appliances 1,077.46Cooling 11,609.96Heating 8,222.03Hot Water 1,686Source: Authors’ own creationReconstructionof residentialbuildings
                                
   2   3   4   5   6   7   8   9   10   11   12